Cat6 termination patch panel
I knew how to Select the Correct Connector. The reason for this design is physical compatibility. If all the conductors were placed eight across like unshielded Cat6 or Cat5e plugs, there would be no room for them. The bonus benefit of staggering conductors is reduction of crosstalk. As Ethernet cable frequency exceeds MHz, crosstalk starts to become an issue of particular concern. Most of these shielded plugs cannot be terminated with a standard crimp tool.
The reason has to do with the lack of a strain latch built into the plug. Thick shielded cable, and especially thick outdoor shielded cable, is so large that there is no room for that strain latch. Unfortunately, most standard RJ45 crimp tools have a strain latch presser bar.
That presser bar would crush the shielded RJ45 plug since there is no rectangular cut-out for it. This means you need a termination tool that lacks or has the ability to disengage the strain latch presser bar. That tool is shown in this blog. To accept the largest outer diameter shielded cables, Cat6 and Cat6A shielded plugs typically have an external ground tab.
This is where the drain wire will contact the metal of the ground tab to ground the plug to the cable electrically. A screwdriver?! The smooth shaft will be used to straighten out conductors, while you are wearing the glove.
This will save your fingers, trust me. The next step is deciding whether you want to use the TA or TB pattern. It does not matter which one you pick, as long as you stick with it.
Adjust the cutting blade of the cable stripper so that it only makes contact with the cable jacket. This takes practice, and you may have to repeat this step a few times to get the perfect score on the jacket. If you cut through, you likely nicked a conductor and you should cut off the end and start over. Strip off about 2. Use the adjustable knob to achieve the perfect score on the cable jacket. Then t urn the tool two to three times completely around to score. Keep the hollow piece of the jacket--it is your new free tool.
Remove any ripcord, PE tape, or waterproof tape all the way down to the end of the cable jacket using flush cutters. Be careful not to nick any conductors while doing this. Remove the cable shield carefully, followed by the waterproof tape - it may take several cuts. Carefully nip the foil shield right at the end of the jacket and remove it.
Fold the drain wire back to keep it out of the way. Removal of the waterproof tape will require flush cutters. Be extremely careful to not nick a conductor in this process.
The idea is to remove the spline so that it is as even as possible with the top of the jacket. The more spline that protrudes the more difficulty you will have with fully seating the RJ45 plug. Inspect the connector to verify that the wires are fully engaged in the IDC terminals and they are cut properly.
Place a dust cover on the jack for protection. The below diagram shows how an assembled jack looks. Ready to insert into a wall plate or keystone jack patch panel? If you skip the above textual descriptions, go check this video that demonstrates more directly and visually. The below guidance video mainly focus on terminating FS Cat6 bulk cable into the Cat6 unshielded toolless keystone jack module:.
Well, there you have it—a ready-to-go keystone jack termination for your Cat5e and Cat6 cables. Have you acquired this skill after going through all the steps? In this tutorial, we have tried to make steps more intuitive and helpful for you. If you have learned how to terminate a keystone jack, why not have a try? Hope your networking is smooth! Diagram Explanation 2 standard pairs on the right and 2 variable pairs on the left. Including common mistakes and what to look out for. Pay attention to the details and you will be able to wire a network properly, or inspect a home network before you buy a house, or keep a contractor honest.
It is a life skill, like knowing how to change your oil, or fix a faucet, only far easier to learn and do. You are welcome future-past readers. The better the cabling in this respect, the higher data per second specification you can run along it. It means Cat7 has a better chance of being able to negotiate higher rate link over a given distance, given equipment that offers that higher rate.
Regarding your original question, the primary concern should not be a line rate, it should be reliability. Outer cable shell is there not only to contain fire, but also to relieve strain from the pairs and keep minimum radius within sane limits. What you have right now is even if these wires are attached to the outer ear on the panel with a cable tie are they? Even without further mounting in this rack it will slowly pull this pair off the panel — Peter Zhabin.
Show 3 more comments. Active Oldest Votes. PeterZhabin comment was right on the money. Improve this answer. What does the certification report the installer gave you on the failing cable say? What certification? The installers we're, IMHO incompetents, there was no certification. In fairness, this was not a massive job, and I only expected it to be done competently - I've never saught certification, just competent workmanship.
Unfortunately typical sparky "yes I can do data cabling" crap which is common down under. An installation is not complete and accepted until every cable passes the Category-6 test suite. Until the installation is category certified, it is not suitable for use. Even experienced installers have trouble with Category-6 and Category-6a installations, and something as simple as having the blue wire on top of the blue-white wire at the punchdown can cause the cable to fail the test suite.