Remstar plus m series provider setup mode




















Something only someone else knows how to program. So why is that you don't know how to adjust the pressure setting on your CPAP machine? It's a second procedure that takes only a few pushes of a couple of buttons. The problem is that the manufacturer of your CPAP machine has hidden some controls from you. In fact they've hidden an entire menu of controls found in what is commonly referred to as the "clinician's setup" or "provider setup" mode. Before I begin spilling the beans about the clinician's setup, consider that trip to the pharmacy one more time.

When you think about it, there's an awful lot of trust between you and your doctor, the doctor and the pharmacist, and the pharmacist and you. You've been told what to do, and they're assuming you're going to do it - correctly. You're also assuming your doctor wrote the right prescription and the pharmacist filled it as written. Taking this trust issue a step further, consider the fact that when you get a prescription filled at the pharmacy, you don't have to go get one pill at a time.

You're trusted with the whole bottle of pills and everyone involved is assuming that you're responsible enough not to do anything stupid with those pills. So given the secret of the clinician's setup mode would you suddenly become irresponsible? Untrustworthy and reckless?

Bent on self destruction by way of CPAP machine? It could happen. But I don't think it will. I firmly believe you are your own best primary care provider - that nobody else is looking out for your health and well being as much as you are. I therefore think you should be trusted with the knowledge of how to adjust the pressure setting on your CPAP machine. Don't get me wrong. We sometimes include the full text of articles and documents rather than a simple link because we have found that links frequently 'go bad' or change over time.

We believe this constitutes a 'fair use' of any such copyrighted material as provided for in section of the US Copyright Law. In accordance with Title 17 U. Section , the material on this site and associated discussion forums is distributed without fee or payment of any kind to those who have expressed a prior interest in receiving the included information for research and educational purposes.

If you wish to use copyrighted material from this site for purposes of your own that go beyond 'fair use', you must obtain permission from the copyright owner.

When it comes to our health, we need to realize that contrary to the claims of some health care professionals no one is looking out for your personal health as much as you. Apnea Board was created to promote ' patient empowerment '-- we believe patients are their own best primary care provider. You can and should be trusted with the knowledge of how to adjust pressure settings on your own CPAP machine.

If you use common sense and take simple precautions, you can safely and properly fine-tune your CPAP settings to enhance the effectiveness of your treatment. We're not providing medical advice here, so we recommend you consult with a qualified sleep doctor before making any changes to sleep apnea therapy. You should never change settings on your CPAP machine without first having a basic understanding of how to properly make such adjustments.

CPAP pressures should be changed slowly, in small increments, over a long period of time, taking note of how you feel after each change. For a detailed explanation of how to determine the optimum pressure on your CPAP machine, click here.

Getting into the clinician setup mode on your CPAP machine is pretty simple, really. If you'd like assistance or advice from fellow Sleep Apnea patients, please join the Apnea Board Forum and ask any question you like.

Apnea Board is an educational web site and we survive on the kindness of our members. If you have benefited from our CPAP setup instructions, the manuals or the forum, please consider donating a small amount to help us pay for our increased bandwidth hosting costs. If you would like to donate using a major credit card , please click on the 'DONATE' button below to use PayPal for your donation you do not need a PayPal account to use your credit card :.

The 3 buttons must be held down until the screen says 'Entering Clinician Menu'. To receive the full Clinician Manual via email, please refer to Section Three below. Respironics REMstar Auto older pre standard unit , not 'M' series, not the PR System One : you can enter the setup menu by holding down the Ramp button and both of the right and left arrow buttons under the display window, while plugging in the CPAP.

The 3 buttons must be held down until the setup screen starts. Once the device beeps twice, release the buttons. After you hear the two beeps, you'll see the word setup in the lower right corner of the LCD screen.

When you select setup you'll be in the clinician's mode where you can adjust every feature of the CPAP machine, including the pressure setting. Supply power to the device: first, plug the socket end of the AC power cord into the power supply. Then plug the pronged end of the AC power cord into an electrical outlet that is not controlled by a wall switch. Finally, plug the power supply cord's connector into the power inlet on the back of the device.

Once the device is powered, the home screen appears it is a large box on the screen with four little boxes you can select by turning the control wheel. Turn the wheel to toggle between the 4 options and highlight 'setup'. Once setup is highlighted press and hold both the control wheel and ramp button on the device for at least 5 seconds. You will hear a double beep and the provider mode screen will appear.

Also, you should remove the smart card prior to making adjustments, otherwise it will revert to the previous settings. Once the device is powered, press and hold both the control dial and the Ramp button on the device for at least 5 seconds.

You are now in Provider Mode. To adjust a setting, rotate the control dial to your desired menu option, then press the control dial to select that setting. Rotate the control dial to change the setting. Press the control dial again to save the change.

Respironics SleepEasy: Plug in the machine while simultaneously pressing the plus and minus buttons on top of the machine. The LCD shows the pressure setting along with an icon of a open padlock.

To move between options, press the ramp button. The plus and minus buttons adjust the increments. Then, firmly hold down both the ramp and power button while plugging the cord into the machine at the same time. When you do so, the 'unlock' icon appears and the blower starts up.

You can then navigate through the menu to change pressures. Press the secret button and the Information Access button simultaneously for 2 or 3 seconds. The CPAP machine will now be in the provider setup mode. Press the Information Access button to cycle through the list of adjustable settings, and use the arrow buttons to make adjustments.

Invacare Polaris EX and possibly other Invacare models : While in stand-by press and hold both up and down arrows for about 15 seconds. Press up arrow for setup. Use up and down arrows to adjust each setting. Press the large Invacare enter button to go to the next setting.

Use a manometer to adjust exact pressure output. When you get into the pressure set mode you will first be able to set adjust altitude, which is indicated by a drawing of a mountain range on your screen. Use the Up and Down keys to change the pressure setting.

Lastly, push the bottom button again to exit programming mode. Simply push and pull down and it should slide off, under that there is a black dial that you turn up or down to change the pressure. Right in front of the adjuster knob is an LCD window that will give you the current pressure setting. Press and hold the button in the middle of the SmartDial, and use your other hand to turn the SmartDial in a clockwise direction until you return to the 12 o'clock postion.

Do not release the Smart Dial button while turning. Turn the SmartDial back counter clockwise one position while still holding down the button and the settings in the Clinician Menu will appear.